cart Shopping Cart CART (0)
TESTS  GENERALLY HAVE SHELF LIVES OF 6+ MONTHS

Pentest : How to Test

How to Use Pentest
The methods of testing are the same for both Pentest products with the D4D being more sensitive. Pentest is designed to be used over the largest surface area possible, giving you the best chance at achieving a readable colour reaction.

 D4D includes a TEST paper,  a "Control" paper, test pen and colour chart.
 Meth-X has two test papers, test pen and colour chart
9677215-410 9995180-92 9536890-138
 
  • Open the foil packaging. Take all of the  contents out of  the pouch.(Test pen, colour chart, and two papers)
  • Read instructions carefully before use
  •  USE one paper peeling back the cover,  this will be the TEST paper, TAKE CARE NOT TO CONTAMINATE THE PAPER - this test paper should be used on no less than 1 m2  per wall per room, wipe in an upwards motion. For example (1m2 x 4 walls per room)
  • Wipe in an upwards direction on all four walls of the room, and  then return through the room collecting residue from the dirtiest/dustiest areas i.e. above doors/window frames, door handle, light fittings, extraction fans etc. Repeat this step with a NEW TEST paper in other rooms.
  • When ready to colour test, take the other paper (CONTROL paper ) & peel back the cover, taking care not to touch  or contaminate.  Hold the tube upright, & squeeze to break the inside ampule of the test pen at ‘1’ where indicated.
  •  Hold the cap with your finger and shake well for 5 seconds. Once mixed with the active ingredient, tip  the pen back and remove the small pen cap.
    You are now ready to test.
  • Pointing the pen away from your body, drip 2 drops on the control paper, Drip the remaining drops on the paper used for testing. let it dry (90 sec)
  • Compare test to control and  if a colour variance is observed in the test check against the colour chart (not including dust) It is normal to get multiple colours on single tests.
  • Only colours similar to the colour chart should be considered as positive results. It is normal to have anything from dirty dusty orange to bright orange.
  • For each test a new test paper must be used.
  • Once ampule is broken, the test should be used within 1 hour.
  • Any positive colour reaction may take 90 seconds or slightly longer to fully develop, depending on the quantity and purity of the substance being tested.
  • Used paper will gradually turn brownish as a result of oxidation.
  • Discard test after use.
  • Keep out of reach of children.  In case of eye or skin contact, flush well with water.
     
D4D has a detection capability of 64ng/mm2 of testing paper. It can be difficult to extract residue from porous surfaces, effectively you need to attract the minimum 64ng/mm2 of test paper for D4D to achieve a colour reaction
Picture1 D4D-476 Picture2 Picture3 D4D-185
Picture4-125 Picture5-582 Picture6-616
Picture7-103 Picture8-548 Picture9-249
Picture10-287 Picture11-543 Picture12-295
Picture13-709 Picture14-893 Picture15-90
Colour chart  (above) and test potentially indicating Methamphetamine, Amphetamine and Cannabis.
Above:  Positive test for Methamphetamine later to confirmed to have a lab tested level of 0.7mg/100cm2
Please note: DO NOT overlap drips on the control paper as this may create a false colour reading (as in picture above. )